Mfg Part Number: CD5-Z14-1
Alternate P/N: CD5Z141
NSN : 5925-01-330-8678
NIIN : 013308678
CAGE Code : 74193
Manufacturer: Eaton Corp
Item Name : Circuit Breaker
Thank you for your interest in our available parts and components on NSN Target. Circuit Breaker is an item listed with the part number CD5-Z14-1, and it is manufactured by Eaton Corp. This particular item CD5-Z14-1 is currently available for purchase through our website today, and our team of industry experts are on standby 24/7x365 to provide rapid lead-times and competitive pricing. To begin the purchasing process, we invite you to fill out and submit an Instant RFQ form as provided through our website. Once received, a member of our staff will reach out to you in 15 minutes or less to provide a quote that has been personalized to fit your individual needs.
NSN Parts is a website that is owned and operated by ASAP Semiconductor, and we serve as a leading independent distributor of NSN parts and components that serve many industries and applications. Throughout our extensive part and manufacturer catalogues, we carry a variety of top requested components that you may need, including CD5-Z14-1 with NSN 5925013308678 and other parts manufactured by Eaton Corp. Quality is of the utmost importance to us at NSN Parts, and we have established ourselves as an FAA AC 00-56B, AS9120B, and ISO 9001:2015 certified enterprise. Get started today with a personalized quote and experience how we are revolutionizing the parts procurement process.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-330-8678 Item Description: Circuit Breaker | 5925 | 013308678 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
Cd5-Z14-1 | 5 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AAQL | BODY STYLE | MULTIPOLE-MULTIPLE ACTUATOR TYPE |
ABTD | MOUNTING SLOT WIDTH | 0.164 INCHES NOMINAL |
ADAQ | BODY LENGTH | 4.740 INCHES MINIMUM AND 4.760 INCHES MAXIMUM |
ADAT | BODY WIDTH | 5.180 INCHES MAXIMUM |
ADTV | CASE MATERIAL | PLASTIC |
AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 3.537 INCHES MINIMUM AND 3.557 INCHES MAXIMUM |
AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 2.740 INCHES MINIMUM AND 2.760 INCHES MAXIMUM |
AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
AJEC | BOSS HEIGHT | 0.209 INCHES MINIMUM AND 0.229 INCHES MAXIMUM |
AJWX | MOUNTING SURFACE TO TERMINAL END DISTANCE | 3.475 INCHES MINIMUM AND 3.495 INCHES MAXIMUM |
APNQ | ARC QUENCHING METHOD | MAGNETIC BLOWOUT |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 10 THREADED HOLE AND 5 SLOT |
BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 10.0 AMPERES AC FIRST LOCATION |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 10.0 AMPERES AC SECOND LOCATION |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 10.0 AMPERES AC THIRD LOCATION |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 5.0 AMPERES DC FIFTH LOCATION |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 5.0 AMPERES DC FOURTH LOCATION |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 140.0 DC FOURTH LOCATION |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 240.0 AC FIRST LOCATION |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 240.0 AC THIRD LOCATION |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 5000.0 AC THIRD LOCATION |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 5000.0 DC FOURTH LOCATION |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONS |
CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY ALL LOCATIONS |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 125.0 ALL LOCATIONS |
CPRQ | RESET METHOD | MANUAL |
CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP FIFTH LOCATION |
CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP FOURTH LOCATION |
CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES/RELAY TRIP FIRST LOCATION |
CQQC | TRIP RELEASE DUTY CYCLE | CONTINUOUS FIRST LOCATION |
CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 20.000 MINIMUM AT 200 PCT THIRD LOCATION AND 100.000 MAXIMUM AT 200 PCT THIRD LOCATION |
CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 25.000 MINIMUM AT 200 PCT FIFTH LOCATION AND 95.000 MAXIMUM AT 200 PCT FIFTH LOCATION |
CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 25.000 MINIMUM AT 200 PCT FOURTH LOCATION AND 95.000 MAXIMUM AT 200 PCT FOURTH LOCATION |
CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | VIBRATION RESISTANT AND SHOCK RESISTANT AND MOISTURE RESISTANT AND SALT SPRAY PROOF |
FREQ | FREQUENCY IN HERTZ | 60.0 FIRST LOCATION |
FREQ | FREQUENCY IN HERTZ | 60.0 SECOND LOCATION |
FREQ | FREQUENCY IN HERTZ | 60.0 THIRD LOCATION |
TTQY | TERMINAL TYPE AND QUANTITY | 12 THREADED STUD |
CMLP | THREAD QUANTITY PER INCH | 32 |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 240.0 AC SECOND LOCATION |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 5000.0 DC FIFTH LOCATION |
CPRK | AUXILIARY TRIP COIL VOLTAGE TYPE AND RATING IN VOLTS | 25.0 DC NOMINAL FIRST LOCATION |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 140.0 DC FIFTH LOCATION |
CPRW | ACTUATOR FUNCTION | TRIP-RESET |
CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP SECOND LOCATION |
CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP THIRD LOCATION |
CQJX | NOMINAL THREAD SIZE | 0.138 INCHES |
CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 20.000 MINIMUM AT 200 PCT FIRST LOCATION AND 100.000 MAXIMUM AT 200 PCT FIRST LOCATION |
THSD | THREAD SERIES DESIGNATOR | UNC |
AEBQ | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH | 1.016 INCHES MINIMUM AND 1.036 INCHES MAXIMUM |
AEHA | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 1.016 INCHES MINIMUM AND 1.036 INCHES MAXIMUM |
AKPX | POLE QUANTITY | 5 |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 5000.0 AC FIRST LOCATION |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 5000.0 AC SECOND LOCATION |
CPRJ | TRIP RELEASE METHOD | MAGNETIC-HYDRAULIC ALL LOCATIONS |
CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 5 TOGGLE |
CPRX | ACTUATOR POSITION DESIGNATION | AT EACH POLE |
CPRY | EXTERNAL ACTUATOR LINKAGE ARRANGEMENT | ONE, TWO, THREE, FOUR, AND FIVE LINKED |
CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 20.000 MINIMUM AT 200 PCT SECOND LOCATION AND 100.000 MAXIMUM AT 200 PCT SECOND LOCATION |
FEAT | SPECIAL FEATURES | FULL LENGTH BARRIERS BETWEEN POLES INCLUDED |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |
We Hope that You Will Visit Us Again the Next Time You Need NSN Parts and Make Us Your Strategic Purchasing Partner.