Mfg Part Number: 130-029-1
Alternate P/N: 1300291
NSN : 5950-00-549-1969
NIIN : 005491969
CAGE Code : 97499
Manufacturer: Bell Helicopter Textron Inc
Item Name : Transformer Power
Thank you for your interest in our available parts and components on NSN Target. Transformer Power is an item listed with the part number 130-029-1, and it is manufactured by Bell Helicopter Textron Inc. This particular item 130-029-1 is currently available for purchase through our website today, and our team of industry experts are on standby 24/7x365 to provide rapid lead-times and competitive pricing. To begin the purchasing process, we invite you to fill out and submit an Instant RFQ form as provided through our website. Once received, a member of our staff will reach out to you in 15 minutes or less to provide a quote that has been personalized to fit your individual needs.
NSN Parts is a website that is owned and operated by ASAP Semiconductor, and we serve as a leading independent distributor of NSN parts and components that serve many industries and applications. Throughout our extensive part and manufacturer catalogues, we carry a variety of top requested components that you may need, including 130-029-1 with NSN 5950005491969 and other parts manufactured by Bell Helicopter Textron Inc. Quality is of the utmost importance to us at NSN Parts, and we have established ourselves as an FAA AC 00-56B, AS9120B, and ISO 9001:2015 certified enterprise. Get started today with a personalized quote and experience how we are revolutionizing the parts procurement process.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-00-549-1969 Item Description: Transformer Power | 5950 | 005491969 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
130-029-1 | 6 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
CRMJ | WINDING POWER RATING | 2.0 VOLTS-AMPERES SINGLE COMPONENT 3RD SECONDARY17.16 VOLTS-AMPERES SINGLE COMPONENT 2ND SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 10.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY26.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 115.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 115.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY115.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 26.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY99.60 AC VOLTS NOMINAL SINGLE COMPONENT 2ND PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 5.00 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY10.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 99.60 AC VOLTS NOMINAL SINGLE COMPONENT 2ND PRIMARY115.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
FEAT | SPECIAL FEATURES | 2 PRIMARY WINDINGS; 5 SECONDARY WINDINGS |
TTQY | TERMINAL TYPE AND QUANTITY | 1 CONNECTOR, RECEPTACLE |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHEDNOT ESTABLISHED |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 5.031 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP5.031 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 4.571 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP4.571 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABTB | MOUNTING HOLE DIAMETER | 0.202 INCHES MINIMUM SINGLE GROUP AND 0.202 INCHES MINIMUM SINGLE GROUP AND 0.208 INCHES MAXIMUM SINGLE GROUP0.208 INCHES MAXIMUM SINGLE GROUP |
ACZB | FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT400.0 HERTZ NOMINAL SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENTSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
ADAQ | BODY LENGTH | 6.000 INCHES MAXIMUM6.000 INCHES MAXIMUM |
ADAT | BODY WIDTH | 3.938 INCHES MAXIMUM3.938 INCHES MAXIMUM |
ADAU | BODY HEIGHT | 3.375 INCHES MAXIMUM3.375 INCHES MAXIMUM |
AKNA | INCLOSURE TYPE | FULLY INCLOSEDFULLY INCLOSED |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP4 SINGLE GROUP |
AXGY | MOUNTING METHOD | UNTHREADED HOLE SINGLE GROUPUNTHREADED HOLE SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 2 PRIMARY SINGLE COMPONENT AND 2 PRIMARY SINGLE COMPONENT AND 5 SECONDARY SINGLE COMPONENT5 SECONDARY SINGLE COMPONENT |
CRBZ | WINDING OPERATING CURRENT | 1.1 AMPERES AC NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 20.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT 4TH SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 200.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT 3RD SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 660.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT 2ND SECONDARY |
CRMJ | WINDING POWER RATING | 0.1 VOLTS-AMPERES SINGLE COMPONENT 4TH SECONDARY2.0 VOLTS-AMPERES SINGLE COMPONENT 3RD SECONDARY |
CRMJ | WINDING POWER RATING | 126.5 VOLTS-AMPERES SINGLE COMPONENT 1ST SECONDARY |
CRMJ | WINDING POWER RATING | 17.16 VOLTS-AMPERES SINGLE COMPONENT 2ND SECONDARY126.5 VOLTS-AMPERES SINGLE COMPONENT 1ST SECONDARY |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |
We Hope that You Will Visit Us Again the Next Time You Need NSN Parts and Make Us Your Strategic Purchasing Partner.
Request for Quote