Mfg Part Number: BX-9109
Alternate P/N: BX9109
NSN : 5950-00-426-2675
NIIN : 004262675
CAGE Code : 85323
Manufacturer: Baltimore Transformer Company
Item Name : Transformer Power
Thank you for your interest in our available parts and components on NSN Target. Transformer Power is an item listed with the part number BX-9109, and it is manufactured by Baltimore Transformer Company. This particular item BX-9109 is currently available for purchase through our website today, and our team of industry experts are on standby 24/7x365 to provide rapid lead-times and competitive pricing. To begin the purchasing process, we invite you to fill out and submit an Instant RFQ form as provided through our website. Once received, a member of our staff will reach out to you in 15 minutes or less to provide a quote that has been personalized to fit your individual needs.
NSN Parts is a website that is owned and operated by ASAP Semiconductor, and we serve as a leading independent distributor of NSN parts and components that serve many industries and applications. Throughout our extensive part and manufacturer catalogues, we carry a variety of top requested components that you may need, including BX-9109 with NSN 5950004262675 and other parts manufactured by Baltimore Transformer Company. Quality is of the utmost importance to us at NSN Parts, and we have established ourselves as an FAA AC 00-56B, AS9120B, and ISO 9001:2015 certified enterprise. Get started today with a personalized quote and experience how we are revolutionizing the parts procurement process.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-00-426-2675 Item Description: Transformer Power | 5950 | 004262675 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
Bx-9109 | 6 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHEDNOT ESTABLISHEDNOT ESTABLISHED |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.297 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP2.297 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP2.297 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.859 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP1.859 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP1.859 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ACZB | FREQUENCY RATING | 50.0 HERTZ NOMINAL SINGLE COMPONENT OR 50.0 HERTZ NOMINAL SINGLE COMPONENT OR 50.0 HERTZ NOMINAL SINGLE COMPONENT OR 60.0 HERTZ NOMINAL SINGLE COMPONENT60.0 HERTZ NOMINAL SINGLE COMPONENT60.0 HERTZ NOMINAL SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENTSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENTSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
ADAQ | BODY LENGTH | 3.063 INCHES NOMINAL3.063 INCHES NOMINAL3.063 INCHES NOMINAL |
ADAT | BODY WIDTH | 2.625 INCHES NOMINAL2.625 INCHES NOMINAL2.625 INCHES NOMINAL |
ADAU | BODY HEIGHT | 4.250 INCHES NOMINAL4.250 INCHES NOMINAL4.250 INCHES NOMINAL |
AEHZ | MAXIMUM OPERATING TEMP | 50.0 DEG CELSIUS50.0 DEG CELSIUS50.0 DEG CELSIUS |
AKNA | INCLOSURE TYPE | HERMETICALLY SEALED WITH OILHERMETICALLY SEALED WITH OILHERMETICALLY SEALED WITH OIL |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP4 SINGLE GROUP4 SINGLE GROUP |
AXGY | MOUNTING METHOD | THREADED STUD SINGLE GROUPTHREADED STUD SINGLE GROUPTHREADED STUD SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 1 PRIMARY SINGLE COMPONENT AND 1 PRIMARY SINGLE COMPONENT AND 5 SECONDARY SINGLE COMPONENT5 SECONDARY SINGLE COMPONENT5 SECONDARY SINGLE COMPONENT |
CQJX | NOMINAL THREAD SIZE | 0.164 INCHES SINGLE GROUP0.164 INCHES SINGLE GROUP0.164 INCHES SINGLE GROUP |
CRBZ | WINDING OPERATING CURRENT | 15.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT 2ND SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 18.5 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT 3RD SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 25.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT 1ST SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 600.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT 4TH SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 2100.00 DC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY330.00 DC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 2100.00 DC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY2100.00 DC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 2100.00 DC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY6.30 DC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY6.30 DC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 330.00 DC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY330.00 DC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 35.00 DC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY35.00 DC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY |
THSD | THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |
TTQY | TERMINAL TYPE AND QUANTITY | 15 TURRET |